TradeTools—Renegade & Renegade Industrial Portable Air Compressors

PRA number

2016/15447

Published date

Product description

Assorted Renegade and Renegade Industrial Portable Air Compressors sold between January 2013 and June 2016.
Incorrect Rating Plate with Highlighted Error V1.0
Identifying features
Assorted Models. Please visit www.tradetools.com/information-and-recalls for details.

Other identifying numbers

Assorted Models. Please visit www.tradetools.com/information-and-recalls for details.

Reasons the product is recalled

The maximum design pressure and hydrostatic test pressure stated on the name plates are incorrect and state higher pressures than calculated by design drawings.

The hazards to consumers

There is a possibility that after any form of modification to the compressor, its safety features or the pressure vessel, consumers may exceed the maximum pressure of the tank and may cause a rupture to the pressure vessel, potentially injuring those surrounding.

What consumers should do

Consumers must not modify their compressors, safety features or the pressure vessel so that they produce more than 990kpa (143psi) of maximum stored pressure. Owners and users of the affected compressors should visit their nearest TradeTools store to arrange for a new rating plate with the correct lower pressure values to be affixed to their compressors.

Supplier

Traders who sold this product

TradeTools Pty Ltd
TradeTools Regional Pty Ltd

Where the product was sold

New South Wales
Queensland
Victoria

Dates available for sale

-

Recall advertisements and supporting documentation

Responsible regulator

Australian Competition and Consumer Commission is the responsible regulator for this recall.

Product category